1) Construction
2) Pair Identification
| Pair 1 |
Blue/White w/Co-extruded Blue Strip on White Single |
| Pair 2 |
Orange/White w/Co-extruded Orange Strip on White Single |
| Pair 3 |
Green/White w/Co-extruded Green Strip on White Single |
| Pair 4 |
Brown/White w/Co-extruded Brown Strip on White Single |
3) Characteristics
Installation Temperature: 0℃ to 60℃ Operation Temperature: -20℃ to 60℃
Capacitance: 20pf/ft nominal
DC Resistance/Unbalance: 28.6 ohms/1000’Max/5% Max
Dielectric Breakdown: 2500 Volts DC Conductor to Conductor
Attenuation: ≤2.320•νfred + 0.238•fred 0.772≤fred≤16
Structural Return Loss: ≥12 1≤fred≤10
≥12 – 10 log(fred/0.772) 10≤fred≤16
Near end Cross-Talk: ≥43-15 log(fred/0.772) 0.772≤fred≤16
Nom. Velocity of propagation, NVP 62% Plenum, 71% Non-plenum
4) Electric Performance
|
Frequency
MHz
|
Attenuation (dB/100m)
|
Near End Cross Talk (dB)
|
Structural Return
Loss (dB)
|
|
EIA/TIA 568
Category 3
|
EIA/TIA 568
Category 3
|
|
0.772
|
2.2
|
43
|
NA
|
|
1.0
|
2.6
|
41
|
12
|
|
4.0
|
5.6
|
32
|
12
|
|
8.0
|
8.5
|
27
|
12
|
|
10.0
|
9.7
|
26
|
12
|
|
16.0
|
13.1
|
23
|
10
|
5) Approval:
UL CSA CE
6) Jacket Color:
Gray, White, Blue, Orange, Purple, Green, Red, Yellow, Black etc.
|